Electrical cord safety inspection checklist copies of this form should be maintained by department department cord gauge amp rating optional date cord identifier mgfr optional inspector s name instructions.
Electrical cord inspection frequency.
Many electrical defects are detectable by visual inspection for example damaged cords.
Regular testing can detect electrical faults and deterioration that cannot be detected by visual inspection.
The maximum formal inspection term for a hotel in general is 5 years whereas the maximum formal inspection term for a swimming pools is only 1 year.
2010 in service safety inspection and testing of electrical equipment outlines inspection testing tagging methods and frequency.
The nature and frequency of inspection and testing depends on factors such as the nature of the electrical equipment how it is used and its.
Electrical safety inspection checklist.
Osha requires a variety of inspections for electrical cords and equipment.
These inspections include a daily visual condition check a quarterly electrical continuity check for cords and a ground fault check for ground fault circuit interruption gfci devices.
The frequency of inspection and testing will vary depending on the nature of the workplace and the risks associated with the electrical equipment.
Electrical hazards electrical hazards can be found in nearly every roofing work site.
Use this template to assess the compliance of electrical safety measures for a given worksite.
1910 334 a 2 i portable cord and plug connected equipment and flexible cord sets extension cords shall be visually inspected before use on any shift for external defects such as loose parts deformed and missing pins or damage to outer jacket or insulation and for evidence of possible internal damage such as pinched.
Extension cords power strips and surge protectors can be safe and effective during normal use but they.
The nature and frequency of inspection and testing depends on factors such as the type of electrical equipment the operating environment and how it is used see tables 1 and 2.
Be aware that a piece of electrical equipment that has a test tag does not necessarily mean that the equipment is in a safe state of repair.
Osha 1910 399 defines a ground fault circuit interrupter or gfci as a device whose function is to interrupt the electric circuit to load when a fault current to ground exceeds some predetermined value that is less than that required to operate the over current protective device of the supply circuit.
This means that the swimming pool should have a full formal inspection test annually irrespective of the rest of the hotel s electrical installation.
Whether the hazard is posed by worn or damaged power tools or cords improperly grounded tools or equipment or the presence of standing water it is the responsibility of the contractor to make sure the tools and equipment.